Summary0025379: Quantity of incorrect wires in the analysis and in the healing reports doesn't match
DescriptionShape Healing exercise reports different figures for the same analyzing /fixing types of entities, for example after Step 4 it reports:
6 wires - OK;
20 wires - incorrect edges sequence;
1 wire - incorrect edges orientation.
After Step 5 (fix) it reports:
4 wires - OK;
23 wires - incorrect edges sequence is fixed.
See the attached pictures too.
Steps To ReproduceRun Sample ShapeHealing.exe
Follow the instruction at the documentation for "..\training\slides\en\shapehealing.html".
Process steps from 1 till 5 including.
TagsNo tags attached.
Test case number
Attached Files7z file icon ShapeHealing.7z (9,537 bytes) 2014-10-15 16:05

- Relationships

-  Notes
(0064029)
szy (developer)
2017-02-28 15:24

Process it, please.
(0068692)
szy (developer)
2017-07-25 18:45

Hi Galina,
Dispatch, please to somebody from shapehealing pool the issue.

- Issue History
Date Modified Username Field Change
2014-10-15 16:05 szy New Issue
2014-10-15 16:05 szy Assigned To => szv
2014-10-15 16:05 szy File Added: ShapeHealing.7z
2016-11-09 15:31 szy Assigned To szv => szy
2016-11-09 15:31 szy Status new => assigned
2016-11-09 15:31 szy Target Version 7.1.0 => 7.2.0
2017-02-28 15:24 szy Note Added: 0064029
2017-02-28 15:24 szy Assigned To szy => gka
2017-07-21 14:15 szv Target Version 7.2.0 => 7.3.0
2017-07-25 18:45 szy Note Added: 0068692
2018-06-08 16:19 bugmaster Target Version 7.3.0 => 7.4.0*