MantisBT
Mantis Bug Tracker Workflow

View Revisions: Issue #25341 All Revisions ] Back to Issue ]
Summary 0025341: Visualization - disallow displaying object as part of connected one and as a free one at the same time
Revision 2014-10-20 18:29 by kgv
Steps To Reproduce Minimal test case:
pload MODELING VISUALIZATION
vinit
box b 1.0 1.0 1.0
psphere s 0.5
vdisplay b s

vconnect bs    2 0 0 b s
vconnect bsc   6 0 0 bs
vconnect bscc 10 0 0 bsc
vfit

vremove b

Erasing of original interactive object results to low-level structures to point dead pointers.

Original test case:
pload ALL
vinit
box b 1 1 1
psphere s 0.5
vdisplay b s
vsetlocation s 0 2.5 0
box d 0.5 0.5 3
box d2 0.5 3 0.5
vdisplay d d2

vfit
vconnectto b1 -2 0 0 b
vconnect z 2 0 0 b s
vconnect z2 4 0 0 d d2
vconnect z3 6 0 0 z z2
vconnect z4 10 0 0 z3 z2
vfit
vaddc z4 0 4 0 s
vsetdispmode 1
vtexture b 5
Revision 2014-10-08 17:32 by dbp
Steps To Reproduce pload ALL
vinit
box b 1 1 1
psphere s 0.5
vdisplay b s
vsetlocation s 0 2.5 0
box d 0.5 0.5 3
box d2 0.5 3 0.5
vdisplay d d2

vfit
vconnectto b1 -2 0 0 b
vconnect z 2 0 0 b s
vconnect z2 4 0 0 d d2
vconnect z3 6 0 0 z z2
vconnect z4 10 0 0 z3 z2
vfit
vaddc z4 0 4 0 s
vsetdispmode 1
vtexture b 5


Copyright © 2000 - 2020 MantisBT Team
Powered by Mantis Bugtracker